Module Specifications

Security Relay

The Security Relay (Part No. 9159010) is used for enhancing security between 2N IP One and the connected electric lock. The Security Relay significantly enhances security of the connected electric lock by preventing unlocking due to device tampering.

Specification

Passive switch

NO/NC contact, up to 30 V / 1 A AC/DC

Switched output

  • Where the Security Relay is fed from the device, 9 to 13 V DC is available on the output depending on the power supply (PoE: 9 V; adapter: source voltage of minus 1 V) / 400 mA DC.

  • Where the Security Relay is fed from an external power supply, 12 V / 700 mA DC is available on the output.

Dimensions (w x h x d)

56 x 31 x 24 mm

Weight

20 g

Connectors and Installation

The Security Relay is installed between the device (outside the secured area) and the electric lock (inside the secured area). The Security Relay includes a relay that can only be activated if a valid access card/code is detected on the unit.

The Security Relay is installed on a two-wire cable between the device and the electric lock inside the area to be secured (typically behind the door). The Security Relay is powered and controlled via this two-wire cable and can thus be added to an existing installation. Thanks to its compact dimensions, the device can be installed into a standard mounting box.

pripojeni-bezpecnostniho-rele-au.jpg
  1. 2N IP One 

  2. Door lock

  3. Departure button

Connect the Security Relay to the access unit as follows:

  • To the Active output

Connect the electric lock to the Security Relay as follows:

  • to the switched output

  • to the passive output in series with the external power supply

The Security Relay also supports the Departure button connected to the ‘PB’ and ‘– HeliosIP/2N IP intercom’ terminals. Once the Departure button is pressed, the output is activated for 5 seconds.

Status Signaling

Green LED

Red LED

State

flashing

off

Operational mode

on

off

Activated output

flashing

flashing

Programming mode – waiting for initialization

on

flashing

Error – wrong code

Configuration
  1. Connect the Security Relay to the properly set Security output of the device. Refer to the Configuration Manual for details. Make sure that one LED at least is on or flashing.

  2. Press and hold the Relay RESET button for 5 seconds to switch the device in the programming mode (red and green LEDs flashing).

  3. Activate the output switch using the keypad, telephone, etc. The first code sent from the access unit will be stored in the memory and considered valid. After code initialization, the Security Relay will pass into the operational mode (green LED flashing).

Caution|/-/media/Images/Manuals/css/caution.png Caution

Having reset the factory defaults on a device with firmware 2.18 or higher, remember to reprogram Security Relay using the instructions above.